EmpowerEd Research · Publications

Institutional publication archive

A permanent, searchable record of EmpowerEd research. The archive preserves organizational research regardless of which technologies or initiatives are currently active: if a project is retired or superseded, its publications remain.

6 publicationsInternal reports · not peer reviewed

Collection

EmpowerEd Edge — Research & Technical Publications

Six reports, all dated November 27, 2026, analysing one continuous prototype experiment.

Research dashboard →

6 of 6 publications match

EE-TR-001·Technical reportNovember 27, 2026

Extended Thermal Endurance

Engineering & Technology · EmpowerEd Edge

This report combines the historical thermal observation of 26 September 2026 with the thermal checkpoints recorded during the 27 November 2026 prototype investigation. The prototype operated for approximately 12 hours in September and for 6 hours 13 minutes to the designated November endpoint. Three November checkpoints recorded 48.8°C at 2h 45m, and 50.5°C at both 3h 29m and 6h 13m, with firmware throttling status 0x0 at each checkpoint. The original September diagnostic records were not recovered, so no historical throttling behaviour is claimed.

47.2°C

September observation

48.8°C

2h 45m

View institutional recordTechnical report · open access
Internal technical reportNot peer reviewed
EE-TR-002·Technical reportNovember 27, 2026

USB-C Powered Endurance

Engineering & Technology · EmpowerEd Edge

This report documents a 6 hour 13 minute continuous prototype uptime session powered entirely from a laptop USB-C port. The host battery was reported at 100% at the start of the session and at 15% at the designated endpoint, against a 40.747 Wh full charge capacity. Final CPU temperature at the endpoint was 50.5°C and the platform was accessible. The result describes device uptime and endpoint accessibility; it does not establish independently verified continuous application availability or an exact battery-powered runtime.

6h 13m

Uptime

15%

Host battery at endpoint

View institutional recordTechnical report · open access
Internal technical reportNot peer reviewed
EE-TR-003·Technical reportNovember 27, 2026

Offline Network Reliability

Engineering & Technology · EmpowerEd Edge

This report records an ICMP packet test against the Edge prototype's local wireless network, conducted without external internet connectivity. Of 1,145 packets transmitted, 1,120 were received and 25 were lost, giving 97.82% packet delivery and 2.18% packet loss. Round-trip latency measured 1 ms minimum, 13 ms average and 81 ms maximum. These figures describe ICMP behaviour on a local network; they are not application response times and carry no educational performance implication.

97.82%

Packet delivery

13 ms

Average latency

View institutional recordTechnical report · open access
Internal technical reportNot peer reviewed
EE-TR-004·Technical reportNovember 27, 2026

Hardware & Power Delivery Stability

Engineering & Technology · EmpowerEd Edge

This report documents thermal and hardware diagnostics for the Edge endpoint during the 27 November 2026 session. Temperatures were 48.8°C at 2h 45m and 50.5°C at both 3h 29m and 6h 13m, with firmware throttling status 0x0 at all three checkpoints. Endpoint diagnostics recorded a Raspberry Pi 5 at approximately 2.4 GHz, 7.9 GiB total RAM with 510 MiB in use, and a 117 GiB root filesystem at 7% utilisation, with no throttling or undervoltage flags recorded. These are observations under the tested workload, not maximum performance benchmarks.

50.5°C

Peak checkpoint

0x0

Throttling status

View institutional recordTechnical report · open access
Internal technical reportNot peer reviewed
EE-TR-005·Technical reportNovember 27, 2026

Infrastructure Disruption Resilience

Engineering & Technology · EmpowerEd Edge

During the 27 November 2026 endurance session, the operator observed three unexpected external electrical disruptions. The operator reported no noticeable interruption to Edge operation. These are observational findings only: outage durations were not independently recorded, the network test was not synchronised with the outages, and no instrumented continuity measurement was taken.

3

Observed disruptions

None

Reported interruption

View institutional recordTechnical report · open access
Internal technical reportNot peer reviewed
EE-TR-006·Technical reportNovember 27, 2026

Energy Consumption & Efficiency

Engineering & Technology · EmpowerEd Edge

This report analyses 212 battery telemetry measurements collected during the 27 November 2026 session: 191 combined-system measurements, six shutdown-transition measurements and 15 laptop-only baseline measurements. Mean host discharge was 7.619 W with the Edge connected and 3.525 W with the Edge disconnected, an approximately 53.7% observed reduction following disconnection. The difference is a comparison of host discharge under two conditions; it is not an independent measurement of Edge power consumption and implies no guaranteed energy savings.

7.619 W

Combined mean

3.525 W

Laptop-only mean

View institutional recordTechnical report · open access
Internal technical reportNot peer reviewed

Archive policy

Research is preserved even when a project ends.

A technology may have its own project-specific testing page. The institutional archive retains every report, dataset and revision regardless of whether the project is active, retired or superseded. Historical and superseded publications remain discoverable and are labelled rather than removed.

What these records are not

Internal technical reports are not independently peer-reviewed publications. They are produced by EmpowerEd Research, reviewed internally, and published with their limitations attached. No external peer review or accreditation is claimed.