Energy Consumption & Efficiency
EmpowerEd Research · November 27, 2026 · Engineering & Technology · EmpowerEd Edge
The full report is published and readable at the link above. The institutional record on this page remains the authoritative version of the publication.
Abstract
This report analyses 212 battery telemetry measurements collected during the 27 November 2026 session: 191 combined-system measurements, six shutdown-transition measurements and 15 laptop-only baseline measurements. Mean host discharge was 7.619 W with the Edge connected and 3.525 W with the Edge disconnected, an approximately 53.7% observed reduction following disconnection. The difference is a comparison of host discharge under two conditions; it is not an independent measurement of Edge power consumption and implies no guaranteed energy savings.
Experimental objectives
- Quantify host battery discharge with and without the Edge connected.
- Describe the distribution of the telemetry rather than relying on a single average.
- Publish the underlying dataset for independent reanalysis.
Methodology
- Battery telemetry was sampled at approximately 60–61 second intervals across the session.
- 191 measurements were recorded with the Edge connected to the host.
- Six measurements were recorded during the shutdown transition.
- 15 measurements were recorded as a laptop-only baseline after the Edge was disconnected.
- Mean, median, standard deviation and an energy-derived average were computed for each condition.
Findings
- 212 total battery telemetry measurements.
- 191 combined-system measurements and 15 laptop-only baseline measurements.
- Six shutdown-transition measurements.
- Mean discharge: 7.619 W combined, 3.525 W laptop-only.
- Median discharge: 7.368 W combined, 3.093 W laptop-only.
- Standard deviation: 2.548 W combined, 1.444 W laptop-only.
- Energy-derived average: 7.842 W combined, 3.750 W laptop-only.
- Approximately 53.7% observed reduction in mean host discharge following Edge disconnection.
Comparative measurements
| Metric | Laptop + Edge | Laptop only |
|---|---|---|
| Samples | 191 | 15 |
| Mean discharge | 7.619 W | 3.525 W |
| Median discharge | 7.368 W | 3.093 W |
| Standard deviation | 2.548 W | 1.444 W |
| Energy-derived average | 7.842 W | 3.750 W |
Observations
- The combined-system distribution is wider than the laptop-only baseline, consistent with a shorter and quieter baseline period.
- The baseline sample is small relative to the combined-system period.
Deployment implications
- The comparison gives an initial indication of the host power cost associated with running the Edge.
- A dedicated inline power meter is required to measure Edge consumption directly.
Research limitations
- The observed difference is not an independently measured Edge power consumption figure.
- No guaranteed energy savings are implied.
- The laptop-only baseline is short (15 samples) and was recorded after the main session.
- Host battery reporting is subject to platform estimation.
- Sampling intervals were approximately 60–61 seconds, so short transients are not resolved.
Supporting evidence
- EE-TR-006 Appendix A — Battery Telemetry dataset (212 rows, five variables)
- Summary statistics for each experimental phase
Supporting dataset
EE-TR-006 Appendix A — Battery Telemetry
212 measurements · five variables · CSV
Open the dataset explorerCitation
EmpowerEd Research (2026). EE-TR-006 — Energy Consumption & Efficiency. EmpowerEd institutional research archive.
Part of the EmpowerEd Edge research collection.