EmpowerEd Research · Project · EmpowerEd Edge
The Edge prototype investigation
A comprehensive record of the 27 November 2026 experiment: what was measured, how it was measured, what the numbers do and do not establish, and where the underlying data lives.
Key indicators
What the session recorded.
Each figure is a measurement from the 27 November 2026 session. None is a benchmark or a general performance claim.
6h 13m
Recorded prototype uptime
Device uptime to the designated endpoint
15%
Host battery remaining
Reported charge at the designated endpoint
50.5°C
Final CPU temperature
Discrete checkpoint at 6h 13m
97.82%
Network packet delivery
ICMP, 1,145 packets transmitted
13 ms
Average local network latency
ICMP round trip, not application response
212
Battery telemetry measurements
Combined, transition and baseline phases
3
Operator-observed electrical disruptions
Durations not independently recorded
One experiment, five analyses
Experimental timeline
Anchors recorded during the session.
Only recorded anchors are shown. Intermediate values are not interpolated and the timeline is not a continuous trace.
Session configuration
- Prototype
- Edge Node 001 (single unit)
- Endpoint
- Raspberry Pi 5
- Power
- Laptop-supplied USB-C power
- Workload
- Lightly loaded prototype with routine instructor computing activity
- Session startHost battery reported at 100%
- 2h 45mThermal checkpoint 48.8°C · throttling 0x0
- 3h 29mThermal checkpoint 50.5°C · throttling 0x0
- 4:05:30 PMBattery anchor 76%
- 6h 13mThermal checkpoint 50.5°C · endpoint accessible
- 7:17:02 PMDesignated endpoint · 15% host battery
- 7:22:20 PM13% during shutdown transition
- 7:37:17 PM11% during shutdown transition
Battery endurance
Reported host charge across five anchors.
The session reached its designated endpoint at 19:17:02 with 15% host battery remaining. Two further anchors were recorded during the shutdown transition.
Reported host battery percentage
Five measurement anchors, including the shutdown transition
The line connects recorded anchors only. It is not a continuous discharge measurement, and no intermediate values were fabricated.
| Anchor | Reported charge | Phase |
|---|---|---|
| Reported initial | 100% | Combined system |
| 4:05:30 PM | 76% | Combined system |
| 7:17:02 PM | 15% | Designated endpoint |
| 7:22:20 PM | 13% | Transition |
| 7:37:17 PM | 11% | Transition |
Full charge capacity
40.747 Wh
Reported by the host at the time of measurement.
Measurement phases · 212 total
Combined-system operation. Laptop and Edge operating together. The designated endpoint was reached at 19:17:02 with 15% host battery remaining.
Shutdown transition. Six measurements recorded after the designated endpoint, at 13% and 11% reported charge.
Laptop-only baseline. Fifteen measurements recorded with the Edge disconnected, used for the comparative energy analysis.
Uptime is not application availability
Deployment implication
Thermal performance
Three discrete checkpoints, not a temperature trace.
Temperatures were read at 2h 45m, 3h 29m and 6h 13m, with firmware throttling status recorded at each.
CPU temperature at recorded checkpoints
27 November 2026
The dashed reference line is the separate September 2026 observation. It is not part of this session.
| Elapsed | Temperature | Throttling |
|---|---|---|
| 2h 45m | 48.8°C | 0x0 |
| 3h 29m | 50.5°C | 0x0 |
| 6h 13m | 50.5°C | 0x0 |
September observation
47.2°C
Approximately 12 hours of continuous operation. A single historical observation. The original September diagnostic records have not been recovered, so the temperature is reported as observed and no throttling behaviour is claimed.
Network performance
Local wireless delivery without external connectivity.
An ICMP test recorded 1,145 packets transmitted, 1,120 received and 25 lost — 97.82% delivery — with 1 ms minimum, 13 ms average and 81 ms maximum round-trip latency.
Packet delivery
ICMP, offline local network
25 packets lost, 2.18% of the test.
Round-trip latency
Minimum, average and maximum
The maximum is far above the average — a single average would conceal that variation.
Test record
- Transmitted
- 1,145
- Received
- 1,120
- Lost
- 25
- Delivery
- 97.82%
- Loss
- 2.18%
- Latency min / avg / max
- 1 / 13 / 81 ms
ICMP latency is not application response time and carries no educational performance implication.
Comparative energy analysis
Host discharge with and without the Edge connected.
212 telemetry measurements: 191 with the Edge connected, 15 laptop-only baseline, six during the shutdown transition.
Comparative host discharge
Mean, median and energy-derived average
Error bars are not shown; the standard deviation is reported in the table. The combined-system distribution is wider than the short baseline.
| Metric | Laptop + Edge | Laptop only |
|---|---|---|
| Samples | 191 | 15 |
| Mean discharge | 7.619 W | 3.525 W |
| Median discharge | 7.368 W | 3.093 W |
| Standard deviation | 2.548 W | 1.444 W |
| Energy-derived average | 7.842 W | 3.750 W |
Observed reduction
≈53.7%
Reduction in mean host discharge following Edge disconnection. This is not an independently measured Edge power consumption figure, and it implies no guaranteed energy savings.
Hardware diagnostics
Endpoint state during the session.
Recorded from the endpoint itself. These describe one unit under the tested workload, not a maximum performance benchmark.
No power-delivery flags
| Diagnostic | Value |
|---|---|
| Endpoint board | Raspberry Pi 5 |
| CPU frequency | Approximately 2.4 GHz |
| Total RAM | 7.9 GiB |
| RAM used | 510 MiB |
| RAM available | 7.4 GiB |
| Root filesystem capacity | 117 GiB |
| Storage utilisation | 7% |
| Throttling / undervoltage flags | None recorded |
Methodology
How the experiment was conducted.
A single prototype was operated continuously on laptop-supplied USB-C power with a lightly loaded system and routine instructor computing activity.
Battery telemetry was sampled at approximately 60–61 second intervals. Thermal readings and throttling status were taken at three discrete checkpoints. A separate ICMP test measured local packet delivery and latency. A short laptop-only baseline followed the main session.
Three unexpected external electrical disruptions were observed by the operator during the session. Outage durations were not independently recorded, and the network test was not synchronised with them.
Research limitations
- One prototype only; results are not a general performance claim for other units or configurations.
- Thermal measurements are three discrete checkpoints, not continuous temperature monitoring.
- The laptop-only baseline is short (15 samples) relative to the combined-system period (191 samples).
- The comparative energy analysis does not independently isolate Edge power consumption.
- Three external electrical disruptions were operator-observed; durations were not independently recorded and the network test was not synchronised with them.
- Device uptime and endpoint accessibility do not establish independently verified continuous application availability.
- Endpoint accessibility does not establish successful completion of an entire educational lesson.
- Network latency was measured with ICMP and does not represent application response time or educational performance.
- Ambient temperature and humidity were not instrumented.
- The September 2026 diagnostic records were not recovered, so historical throttling behaviour cannot be verified.
Related technical publications
Six reports from one experiment.
Each report analyses a different aspect of the same session. All are dated November 27, 2026.
Supporting dataset
EE-TR-006 Appendix A — Battery Telemetry
212 measurements across five variables, sampled at approximately 60–61 second intervals.
Variables
The original CSV is held in a restricted location. The explorer accepts the original export and keeps every row in your browser.
Future research directions
What has not been tested yet.
Research directions, not guaranteed outcomes or committed deployment dates.